Interactive estimate

Range bin visualiser

An FMCW radar sweeps its frequency across a band. The wider that sweep, the finer it can separate two objects by distance. Type in a sweep and a room, and the room is raked into cells of that size.

How wide the frequency sweep is that the receiver samples. Enter the full sweep only if all of it is sampled. 0.25 GHz is 250 MHz.
The middle of the sweep, for example 24 or 60. The sweep must stay above 0 GHz.
From the wall the sensor is on to the far wall.
Example inputs:
    Range resolution, ΔR
    3.75 cmestimate: c ÷ (2 × B)
    Wavelength, λ
    5.00 mmestimate: c ÷ f
    Cells along the room centreline
    about 107room length ÷ ΔR, rounded up

    Schematic plan view from the sensor on the left wall; the width is not to scale and the count is along the centreline only. Each raked band is one range resolution cell: two objects closer together in distance than one cell can merge into a single reflection. Shaded corners are farther from the sensor than the room length and are not modelled. Estimate, not what a product reports.

    The formulas

    ΔR = c ÷ (2 × B)

    λ = c ÷ f

    cells ≈ room length ÷ ΔR, rounded up

    B is the sampled chirp bandwidth and f is the centre frequency, both converted from GHz to Hz. Enter the full sweep as B only if the receiver samples all of it. The sweep is taken to be centred on f, so f minus half of B must stay above 0 GHz. c is the speed of light in vacuum, 299,792,458 m/s, which is exact by the definition of the metre in the SI (BIPM). The prefixes G, M, c and m are the SI prefixes for 109, 106, 10-2 and 10-3. The cell count is along the centreline from the sensor to the far wall; the width in the drawing is schematic.

    Assumptions behind every result

    • ΔR is the ideal range resolution for the bandwidth you enter as sampled. A real product's processing can make the effective resolution coarser.
    • The model uses the speed of light in vacuum as an approximation for air, where radio waves travel very slightly slower.
    • The drawing shows resolution cells, not what a sensor reports. Product-specific reporting gates, zones or areas are outside this model.
    • Range resolution is about distance from the sensor only. Telling apart two people at the same distance but different angles depends on the antennas, which this tool does not model.
    • All results are estimates for understanding the idea, not a specification of any sensor.

    Worked check

    A 4 GHz sweep gives 299,792,458 ÷ (2 × 4,000,000,000) ≈ 0.0375 m, or 3.75 cm. A 250 MHz sweep gives about 60 cm. A 60 GHz centre frequency gives a wavelength of about 5.0 mm, which is why these radars are called millimetre-wave.

    Sources

    1. The fundamentals of millimeter wave radar sensors (white paper), Texas Instruments
    2. The International System of Units (SI Brochure), Bureau International des Poids et Mesures (BIPM)
    3. Terminology, Radar Academy, Texas Instruments
    4. SI base unit: metre (m), Bureau International des Poids et Mesures (BIPM)
    5. SI: Prefixes, Bureau International des Poids et Mesures (BIPM)
    6. Chapter 6: Electromagnetics, Basics of Space Flight, NASA Science